Evaluation of an organic automated rain sampler / by W.M.J. Strachan and H. Huneault.: En36-539/100-1982E-PDF
"An automated rain sampler was designed, built and evaluated as a collecting device for persistent organic chemicals in rain. It consists of a large teflon coated funnel (0.209 m²) with an automated lid and a teflon column containing XAD-2 or 7 resin. The sampler was tested for recoveries and field precision with a number of organochlorine substances and PCB’s frequently found at the nanogram per litre level in rain. Recoveries averaged 86% and the mean coefficient of variation for αz-BHC, lindane and PCB's was 33% under field conditions where samples of 0.4-22 litres of rain were collected. The sampler is recommended for use in network sampling for such substances"--Abstract, p. i.
Permanent link to this Catalogue record:
publications.gc.ca/pub?id=9.945780&sl=0
| Department/Agency |
|
|---|---|
| Title | Evaluation of an organic automated rain sampler / by W.M.J. Strachan and H. Huneault. |
| Series title |
|
| Publication type | Monograph - View Master Record |
| Language | [English] |
| Format | Digital text |
| Electronic document | |
| Note(s) |
|
| Publishing information |
|
| Author / Contributor |
|
| Description | 1 online resource (i, 14 pages) : illustrations. |
| Catalogue number |
|
| Edition |
|
| Subject terms |
Request alternate formats
To request an alternate format of a publication, complete the Government of Canada Publications email form. Use the form’s “question or comment” field to specify the requested publication.Page details
- Date modified: